SEARCH

Found 59 related files. Current in page 1

e60 retrofit

HP EFI - Holley Performance Products

1.0 OVERVIEW The HP EFI Universal Retrofit Kits (P/N 550-500 & 550-501) are designed for engines that have no off-the-shelf port fuel injection manifold available. It comes with almost all the components necessary for complete installation. Other components required are listed in this manual with guidelines for them. 2.0 SKILLS AND EQUIPMENT REQUIRED Various skills and tools are required for the complete installation and successful use of this kit. Machining for the fuel injector bungs and fuel rails requires the use of a Bridgeport mill or similar piece of machining equipment. It is nice to have a digital X/Y axis readout. The injector bungs ideally should be TIG-welded to the intake manifold, which requires an experienced aluminum TIG-welder. They can also successfully be epoxied, but welding will guarantee good durability. The fuel rails will also require tapping and/or machining depending upon the fittings chosen. Hold-downs for the fuel rails will also have to be fabricated. These should be welded to the manifold, but they can be designed to be bolted down. The tuning of the fuel injection system requires that an individual have basic computer and engine tuning skills. A manual is included that includes detailed and comprehensive tuning instructions. NOTE: This kit is a universal kit. The level of skill and fabrication required will vary for every application.

Featured PowerCore Air Cleaners and ... - India Donaldson

Donaldson Featured Parts Original PowerCore® Products Total Filtration Solutions for your Equipment P603577 Ford P604273 GM P606122 Ford P607955 Freightliner P608533 Donaldson PSD08 P608666 Donaldson PSD10 P609086 Ford P610875 GM P613522 Ford P616056 Kenworth F-Series Super Duty 6.0L Diesel Donaldson 7.3L PowerCore® Air Cleaner Kit PowerCore® Air Cleaner F-Series F650 F750 6.0L Diesel F-Series 6.4L Diesel H2 Hummer M2 Series PowerCore® Air Cleaner Silverado Sierra 6.6L Duramax Diesel T660 Series Donaldson Featured Parts Original PowerCore® Products PowerCore® Filtration Technology Delivers Improved Filtration Performance! Donaldson has been manufacturing air cleaners with PowerCore Filtration Technology since 1999. Visit www.donaldson.com/aircleaners for additional information on PowerCore air cleaners. PSD PowerCore® Air Cleaners Donaldson's line of PSD Air Cleaners have original PowerCore technology and offer two-stage filtration in a single, compact unit that delivers superior filtration performance in both horizontal and vertical mounting options. Severe Duty Air Induction System Retrofit Kit D080020 PSD08 PowerCore® Air Cleaner Assembly Horizontal le ilab Ava ng 2009 Spri D080056 PSD08 PowerCore® Air Cleaner Assembly Vertical 1999*-2003 Ford F250-550 or Excursion with 7.3L Power Stroke® Diesel Engine * Built after January 1, 1999 This retrofit kit is ideal for truck owners who operate their vehicle in dirty and dusty conditions and want longer filter service life and improved engine protection. D090055 PSD09 PowerCore® Air Cleaner Assembly Horizontal Kit X007953 includes the air cleaner assembly, duct, battery tray and blanket, fasteners and installation instructions. Millions of PowerCore® Filters Installed on Original Equipment! D100031 PSD10 PowerCore® Air Cleaner Assembly Vertical PowerCore filters can be easily recognized by their unique corrugated media and will have the original PowerCore identity. D120035 PSD12 PowerCore® Greater Efficiency The straight-through fluted design of PowerCore Filtration Technology is three times more efficient than average conventional pleated filters Air Cleaner Assembly Vertical Engine Protection No media movement, expansion, contraction or bunching, with less dust and dirt passed on to the engine Other Featured Parts Listing Contaminant Encapsulation Dust and dirt won’t dislodge during servicing Expect the Best. Demand the Original. Engine Air Engine Lube, Fuel & Coolant Engine Exhaust Parts and Accessories Mobile Hydraulic Hard Parts and Accessories Donaldson Company, Inc. Minneapolis, MN 55440-1299 www.donaldson.com Brochure No. F111273 (2/09) © 2009 Donaldson Company, Inc. Printed in the U.S.A. Donaldson Company, Inc. reserves the right to change or discontinue any model or specification at any time and without notice. Brochure No. F111257 F111258 F111259 F111262 F111260

Fuel Cell-Powered Lift Truck FedEx Freight Fleet Deployment - U.S. ...

Jonathan King, Program Manager FedEx Freight May 16, 2012 Project ID: H2RA009 This presentation does not contain any proprietary, confidential or otherwise restricted information. Project Overview  Timeline  Barriers • High number of repairs on fuel cells • Operating fuel cells in cold weather • Fueling fuel cells in cold weather • Start: October 1, 2009 • Finish: September 30, 2013 • 58% complete (Feb 29, 2012)  Partners  Budget • Total project funding • DOE: $1,290,646 • FedEx: $1,526,836 Fuel Cell-Powered Lift Truck FedEx Freight Fleet Deployment • Plug Power – GenDrive® system and service provider • Air Products – Hydrogen supplier May 16, 2012 Project ID: H2RA009 PAGE 2 Relevance  Safe and reliable operations of hydrogen material handling equipment (MHE)  Convert an entire MHE fleet at FedEx Springfield, MO facility with fuel cell powered forklifts (class-1)  Demonstrate economic benefits of conversion  Provide cost effective and reliable hydrogen  Spur further forklift fleet conversions  Establish proving ground for hydrogen MHE Fuel Cell-Powered Lift Truck FedEx Freight Fleet Deployment May 16, 2012 Project ID: H2RA009 PAGE 3 Plan and Approach  Install hydrogen fueling equipment  Retrofit 35 electric forklifts to operate using fuel cells • Train forklift operators to fuel hydrogen fuel cells • Train maintenance techs to perform simple repairs and preventive maintenance (PM) on fuel cells  Fuel cell forklift operation and evaluation • Fuel economy • Reliability • Cost • Operator acceptance  Annual assessments Fuel Cell-Powered Lift Truck FedEx Freight Fleet Deployment May 16, 2012 Project ID: H2RA009 PAGE 4 Milestones Milestones Progress Fueling Station Installation Air Products’ completed construction and installation of the fueling equipment. FedEx finished system integration. 100% Hydrogen Safety Plan Worked with Air Products and Plug Power to complete the hydrogen safety plan 100% ►Go/No Go Fueling station tested and operational in June 2010 100% GenDrive Power Unit Build Plug Power completed build of 35 class-1 units in December 2009 and 5 more in December 2010 100% Start-up and Training Start-up and training completed in June 2010 100% Forklift Operation and Evaluation Operation and evaluation started July 2010 Fuel Cell-Powered Lift Truck FedEx Freight Fleet Deployment % Complete May 16, 2012 Project ID: H2RA009 50%

Furniture Feed Style Poke-Thru Devices Product ... - by Legrand

Furniture Feed Style Poke-Thru Devices RC7AFFTC, RC9AFFTC, RC9AM2TC, 4FFATC Series Bring Power & Communication Services to Modular Furniture Systems alker Furniture Feed Style PokeThru Devices are an excellent solution for feeding both power and communication services to modular furniture systems in an open space, above grade floor environment. Every Walker Poke-Thru Device comes with built-in TopGuard protection, an industry-leading design that meets and exceeds UL scrub water exclusion requirements for tile and carpet floors. TopGuard protection prevents RC7AFFTC Furniture Feed Poke-Thru Series water, dirt, or debris from entering not just the power compartment, but also the communication compartment located below the floor, through the service head or floor fittings. All Walker Furniture Feed Style Poke-Thru Devices can be installed on tile, carpet, or wood floors. Each of these devices provides an excellent solution for both new or retrofit construction, with typical applications that include commercial office 4FFATC Dual Service Furniture Feed buildings, financial institutions, and Poke-Thru Series government facilities. Protection from water, dirt, and debris. Features & Benefits ■ TopGuard Protection. Integral design component that prevents water, dirt and debris from entering power and communication compartments. Whenever you see the TopGuard protection icon on any Wiremold product, you’ll know it meets and exceeds UL scrub water exclusion requirements for tile and carpet floors. ■ UL Listed and UL Fire Classified to U.S. and Canadian safety standards for tile and terrazzo. Includes the new UL requirements under UL514A and UL 514C for the scrub water exclusion test for carpet and wood floors. ■ 4FFATC Flush Style Furniture Feed Series provides one 3/4" opening for power and one 1 1/4" opening for communication cabling. Provides largest dual service capacity for furniture feed applications in the industry. UL Listed for both power and communication furniture feed applications.

View Document
by Alexi 0 Comments favorite 85 Viewed Download 0 Times

Resistors, Relays, Thermostats Connectors, Pigtails, Wire Harnesses ..... excellent Protection against Metal Wear and Moisture Absorption for Corrosion Protection. This Product is blended with our MasterChem™ Lubricant Enhancer which provides additional additives to reduce Metal Wear and clean the Condenser internally along with the rest of the System restoring the Thermal Efficiency of the A/C System. These Oils are for R134a only, OEM Service and Retrofit.Page 59-61. MAZDA. .... Friction & Wear. Absorbs Moisture with ...

Air Intake Systems - Donaldson Company, Inc.

Donaldson Endurance air filters are guaranteed to go ... retrofit kit for 7.3L Ford PowerStroke Engine Donaldson Endurance™ air filter line expanded....EPG Housings were one of the first series that featured radial seal technology. Metal end caps on pleated filters were replaced with a urethane end cap design. The unique feature simplified service for mechanics and created a more reliable critical seal between the housing cover and filter. Donaldson Endurance™ extended service filters with Ultra-Web Technology are an option. FPG Housings are ideally suited for smaller engine intake requirements....

Fuel Cell-Powered Lift Truck FedEx Freight Fleet Deployment

May 13, 2011 ... Train forklift operators to fuel hydrogen fuel cells. • Train maintenance technicians to perform simple repairs and preventive maintenance (PM) ... Install hydrogen fueling equipment  Retrofit 35 electric forklifts to operate using fuel cells • Train forklift operators to fuel hydrogen fuel cells • Train maintenance technicians to perform simple repairs and preventive maintenance (PM) on fuel cells  Fuel cell forklift operation and evaluation

EF35R Electric Fireplace and Kensington Mantel EL24R Electric ...

EF23R Electric Fireplace and EMOVDC Overton Mantel. EMKNDO Kensington Mantel and Optional. ERKNDO Overmantel Mirror. EF23R Electric Fireplace and ...Recreate the warmth and ambiance of a real fire and easily retrofit into existing wood-burning fireplaces. Simply plug into a standard outlet and enjoy realistic flames and convenient on/off operation when you want to have a fire. Available in 24” and 30” models to fit a variety of fireplace sizes. Awarded the 2007 Vesta award for electric fireplaces, stoves and logs....

R-134a Retrofit & Charging Kit - Technautics

This kit provides the basic tools and total amount of R-134a Oil Charge and R-134a Refrigerant required for conversion of a refrigerant R-12 to R-134a. Check TECHNAUTICS Charging Instructions. BEFORE CHARGING: Check Warning on Charge Cans. - Any remaining R-12 Refrigerant in your System must be removed without venting by a certified mechanic with approved R-12 recovery equipment....

1999*-2003 Ford F250-550 or Excursion with 7.3L Power Stroke ...

1999*-2003 Ford F250-550 or Excursion with 7.3L ... This retrofit air induction system kit is ... Air Filter. P606122. 2U2Z-9601-BA. FA-1757. Clean air travels on to ...

« previous  123456