SEARCH

Found 413 related files. Current in page 1

contoh soalan persamaan linear

E.coli: As an Alternate Model for Phototoxicity  Assessment of Drugs

Phototoxic and photoallergic reactions represent skin reactions to the sun, in the presence of photoactive chemicals applied on the skin or taken systemically. They have a highly polymorphic clinical presentation – photo contact urticaria, eczema on sun-exposed areas sometimes with erythema multiforme, exaggerated sunburn, linear phytophotodermatitis, pseudoporphyria, photoonycholysis, dyschromia, and lupus erythematosus. Also, skin cancers are increasingly associated with exposure to photoactive chemicals. There is a geographical and timely variation in the responsible agents, but they are mostly furocumarins from plants, UV filters in sunscreens and cosmetics, and drugs (NSAIDs, antimicrobials, phenothiazines, amiodarone, etc.) Three drugs like Chloramphenicol, Norflox, and Kucil(Fluorouracil) were tested for Phototoxic effect procured from local market and check the ph and absorption spectra and note and solubility of test drug was tried out through different solve

Linear Minimum Variance Unbiased Estimation of  Individual and Population slopes in the presence

Linear Minimum Variance Unbiased Estimation of Individual and Population slopes in the presence of Informative Right Censoring

The Reliability of Musculoskeletal Ultrasound Video  Tracking of Muscle and Tendon Displacement

Lateral epicondylalgia [LE] is most common cause of elbow pain attributed to abnormalities in the extensor carpi radialis and extensor digitorum communis [EDC]. Quantifying the linear displacement using musculoskeletal ultrasound and the Motion Tracking Analysis Program [MTAP] may be useful in characterizing the abnormalities found in elbows with LE. This study investigated the reliability of the operators [i.e. sonologist and sonographer] and the reader [i.e. physiotherapist] in procuring and analyzing ultrasound videos using MTAP.

New Version of Excel Linear Material Cut Optimization Add-In 1DCutX Introduced Angle Cutting

1888PressRelease - Recently released version of linear material cutting optimization add-in 1DCutX for Excel implements support for cut angles different than traditional 90 degrees.

Scirj-Enhancement of Photorefractive Two-Beam Coupling in KNbO3

A theoretical study has been done to investigate the significant enhancement of the photorefractive and photovoltaic effects of a new co-doped potassium niobate crystal (KNbO3: Fe: Ag) as compared to the result obtained for singly doped potassium niobate crystals. The co-doped Ag impurity enters the K site, rather than the typical Nb site, thus changing the local field in the lattice. It is believed that Fe perturbed by the Ag in the K site is responsible for an enhancement of the linear absorption and photocurrent, as well as for the probable increase in the effective trap density. An enhanced trap density is likely the cause of the increased photorefractive counter-propagating two-beam coupling efficiency. http://www.scirj.org/jul-2014-paper.php?rp=P0714157

Pololu 3pi Robot Simplified Schematic Diagram

2008 Pololu Corporation http://www.pololu.com/. Pololu. Pololu 3pi Robot Simplified Schematic Diagram page 1 of 1 rrc03a. D3a. RED. 2.21k. R26a. PD1. D3b. Pololu 3pi Robot Simplified Schematic Diagram J20 + VBAT 1 2 J7 reverse protection Q1 2 1 VIN POWER R4a 1k R4b 1k AVCC B2 2xAAA U3 PB2 (SS/OC1B) PB0 PB1 PB4 PB5 12 13 16 17 PB0 (CLKO/ICP1) PB1 (OC1A) PB4 (MISO) PB5 (SCK) PD2 PD4 PD7 32 2 11 PD2 (INT0) PD4 (XCK/T0) PD7 (AIN1) 1 3 10 9 15 1 VCC VCC 18 20 PD0 (RXD) PD1 (TXD) 30 31 PC0 (ADC0) PC1 (ADC1) PC2 (ADC2) PC3 (ADC3) PC4 (ADC4/SDA) PC5 (ADC5/SCL) ADC6 ADC7 19 22 VCC PD0 PD1 U4 C22 2.2 nF PC1 R13 220 VCC U5 C23 2.2 nF PC2 R14 ADC6 ADC7 220 J4 VCC VCC R15 10k R16 10k microcontroller U6 C24 2.2 nF 2 1 ATmega168 VBOOST 220 C32 0.1 uF 29 PC6 VCC PC6 (RESET) 33 GND 21 GND 5 GND 3 GND 2 Y1 20 MHz VCC 23 24 25 26 27 28 PB6 (XTAL1/TOSC1) PB7 (XTAL2/TOSC2) C18 0.1 uF C21 2.2 nF PC0 R12 6 4 AVCC AREF PD6 (OC0A/AIN0) PD5 (OC0B/T1) PB3 (MOSI/OC2A) PD3 (OC2B/INT1) 7 8 D6 5V zener VCC AVCC 14 PD6 PD5 PB3 PD3 D1b T1 D1a BLUE GND + BUZZER D5 BLUE VOUT pushbutton power circuit BZ1 L2 10 uH GND VIN VOUT 5.0 V linear regulator R33 1k GND B1 2xAAA BTN2 BTN1 + VIN VOUT 9.25 V boost switching regulator SW1 CHARGE VCC VBOOST PC3 R17 220 VCC C26 0.1 uF VCC VCC PB4 PB5 PC6 LCD1 Vss 1 VDD 2 Vo 3 R18 10k RS 4 R/W 6 PD4 DB0 8 R22 DB2 9 10k DB3 10 DB4 11 PB1 DB5 12 PB4 DB6 13 PB5 DB7 14 PD7 U8 reflectance sensor array and IR LED control 7 DB1 220 PB3 PB0 E 2 4 6 PC4 R19 PD2 5 J1 1 3 5 U7 C25 2.2 nF SW2 RESET AVRISP R25b 2.21k programming connection PD7 R25a 2.21k PD1 R26a 2.21k D4b T1 PC5 D3a RED R21 220 LEDON Q4 D3b T1 VCC VBOOST VCC U9 PB3 PD3 AIN1 AIN2 PWMA PD5 PD6 17 16 15 BIN1 BIN2 PWMB PC6 J6 B C R30 20k R31 20k 1 2 A 8x2 character LCD and user pushbuttons 21 22 23 19 VM1 VM2 VM3 ADC6 R27 1k R28 1k R29 1k R32 20k battery voltage sensing circuit 24 13 14 Vcc 20 AO1 AO1 1 2 AO2 AO2 5 6 BO1 BO1 11 12 BO2 BO2 VBAT LCD8X2 7 8 STBY 18 GND 3 4 9 10 PGND1 PGND1 PGND2 PGND2 C27 0.1 uF MO3 © 2008 Pololu Corporation http://www.pololu.com/ page 1 of 1 M2 MO4 MO2 MO1 M1 TB6612FNG motor driver and motors Pololu R20 220 R23 47k 1 2 R26b 2.21k D4a GREEN VCC J5 C28 0.1 uF rrc03a

Universal Grinding Machine for the highest demands - Hardinge Inc.

Splash guard to be used with standard workhead mounted on linear roller bearings Sine bar attachment direct fine angular setting by using gauge blocks when grinding chucked workpieces with inside or outside tapers KEL-UNIVERSAL for grinding jobs in tool and die maker shops, for the grinding of small batches of components or of prototype pieces, for maintenance jobs, laboratories or special machine building facilities. Machine base with high static and dynamic rigidity. Optimal bracing Generously dimensioned and precision scraped V- and flat guideways guarantee a long lifetime of quality Three point set-up, no special foundation required Workhead with its preloaded highprecision roller bearings is designed for a working capacity of up to max. 130 kg between centres or of up to 160 Nm for components taken-up in chucks. Standard working accuracy Roundness for chucked work: Delta R<0.5 µm according to B.S. 3730. Increased working accuracy Delta R<0.2 µm according to B.S. 3730. Accessoires: Lever-operated clamping attachment power chuck KEL-UNIVERSAL Tailstock with preloaded sleeve Sleeve located in preloaded ball bearings Morse taper MT4 retraction of sleeve 30 mm.

SBMPTN 2013 Biologi - Bisa Kimia

Doc. Name: SBMPTN2013BIO999 Doc. Version : 2013-10 | 01. Contoh keberadaan satwa pada suatu habitat yang dijaga dengan baik sebagai upaya pelestarian ex situ adalah… (A) Orang utan di hutan Kalimantan. (B) Cendrawasih di hutan Papua. (C) Rusa di Kebun Raya Bogor. (D) Pesut diSungai Mahakam. (E) Anoa di Pulau Sulawesi 02. Komunitas mikroba yang melekat pada suatu substrat/benda sehingga dapat merusak substrat/benda tersebut disebut… (A) Biodegradator. (B) Bioaktivator. (C) Biokatalis. (D) Biodeposit. (E) Biofilm. 03. Bagian sistem pencernaan yang berperan dalam memecah polipeptida menjadi oligopeptida adalah… (A) Duodenum. (B) Usus besar. (C) Lambung. (D) Jejunum. (E) Ileum. 04. Asam absisat melindungi tanaman yang mengalami kekurangan air melalui mekanisme… (A) Peningkatan pembentukan kutikula. (B) Penurunan tekanan turgor sel penjaga. (C) Peningkatan kecepatan pembelahan sel. (D) Penurunan kecepatan pembentangan sel. (E) Penghambatan pemanjangan sel epidermis. halaman 1 05. Pernyataan yang salah mengenai fotofosforilisasi siklik dan non siklik adalah… (A) Pada fotofosforilisasi non siklik sumber elektron yang memasuki Fotosistem II adalah molekul air, pada fotofosforilisasi siklik, sumber dari elektron adalah Fotosistem I. (B) Pada fotofosforilisasi non siklik penerima elktron terakhir adalah NADP, pada fotofosforilisasi siklik, penerima elektron terakhir adalah Fotosistem I. (C) Hasil dari fotofosforilisasi non siklik adalah ATP, NADPH, dan O2, sedangkan hasil dari fotofosforilisasi siklikhanya ATP. (D) Fotofosforilisasi non siklik melibatkan Fotosistem I dan II, fotofosforilisasi siklik hanya melibatkan Fotosistem II. 06. Perhatikan diagram saluran kreb berikut! Tahap dimana berlangsung hidrasi adalah (A) 1 dan 4 (B) 1 dan 5 (C) 2 dan 6 (D) 3 dan 7 (E) 3 dan 8 Kunci dan pembahasan soal ini bisa dilihat di www.zenius.net dengan memasukkan kode 3117 ke menu search. Copyright © 2013 Zenius Education SBMPTN 2013 Biologi, Kode Soal doc. name: SBMPTN2013BIO999 halaman 2 doc. version : 2013-10 | 07. Perhatikan gambar tahapan mitosis berikut! 10. Grafik berikut menunjukan kinerja insulin sintetis. Tahap telofase, metaphase, anaphase dan profasen ditunjukan oleh urutan angka…

GreatCo. Electric Fireplace Trifold Brochure - Outdoor GreatRoom Co.

Gallery Built-In Fireplace Specifications MODEL HEIGHT WIDTH DEPTH WATTAGE GBI-34 26 1/4” 33 1/2” 11 1/4” 750/1500 GBI-41 31 3/8” 40 3/8” 11 1/4” 750/1500 LF-34 29 3/4” 33 7/8” 1” NA LF-41 34 13/16” 40 3/4” 1” NA FAF-34 29 3/4” 33 7/8” 1” NA FAF-41 34 13/16” 40 3/4” 1” NA ARF-34 29 3/4” 33 7/8” 1” NA ARF-41 34 13/16” 40 3/4” 1” NA COL-COR-RIS-K 45 1/4” 51” 31”  NA COLUMBIA CORNER TV 4 3/4” 39” 16 1/2” NA RIO-34-K / RIO-41-K 44 1/2” / 49” 51” / 58” 16” / 16” NA RIO-34-BOOK CASE / RIO-41-BOOK CASE 32 3/4” / 32 3/4” 48 1/4” / 54 1/4” 15” / 15” NA Electric Fireplaces BU ILT-IN | H D L IN EA R | IN S ERT Model GE-70 Gallery HD Linear Wall-Mount Fireplace Specifications Gallery Electric Insert Fireplace Specifications FIREPLACE OPENING SIZE MODEL HEIGHT WIDTH DEPTH MOUNTING AREA VIEWING SIZE WATTAGE GE-94 26 2/5” 93 7/10” 6” 67”w x 13 3/4”h 75"w x 12"h 1500 GE-78 26 2/5” 78” 6” 63”w x 14.5”h 59 1/10”w x 12”h 1500 GE-70 26 2/5” 70” 6” 50 7/8”w x 13 3/4”h 51 1/5"w x 12"h 26 2/5” 58 3/10” 6” 34 3/8”w x 14 3/4”h 39 2/5"w x 12"h 1500 GE-5O 26 2/5” 50 2/5” 6” 34 3/8”w x 14 3/4”h 31 1/2"w x 12"h 24 1/2” 35 4/5” 6 3/5” 17 3/8”w x 17 7/8”h 20 3/10"w x 12"h 1500 HEIGHT (H) DEPTH (D) WIDTH (OW) MIN MAX HEIGHT (OH) MIN N/A (OD) MAX 21 3/4” FIREPLACE MINIMUM DEPTH 1500 GER-36* WIDTH (W) 1500 GE-58 MODEL 26 1/8” N/A 8 3/8” Model GE-70 Model GE-78 Model GE-58 Model GE-50 28 1/2” 22 5/8” 8 3/4” IS-36 36 1/4” 27” 1” 26 1/8” 36” 21 3/4” 26 4/5” N/A IS-42 Model GE-94 GI-29 42 1/4” 28 1/2” 1”

LM34 Precision Fahrenheit Temperature Sensors - Texas Instruments

The LM34 series are precision integrated-circuit temperature sensors, whose output voltage is linearly proportional to the Fahrenheit temperature. The LM34 thus has an advantage over linear temperature sensors calibrated in degrees Kelvin, as the user is not required to subtract a large constant voltage from its output to obtain convenient Fahrenheit scaling. The LM34 does not require any external calibration or trimming to provide typical accuracies of ± 1⁄2˚F at room temperature and ± 11⁄2˚F over a full −50 to +300˚F temperature range. Low cost is assured by trimming and calibration at the wafer level. The LM34’s low output impedance, linear output, and precise inherent calibration make interfacing to readout or control circuitry especially easy. It can be used with single power supplies or with plus and minus supplies. As it draws only 75 µA from its supply, it has very low self-heating, less than 0.2˚F in still air. The LM34 is rated to operate over a −50˚ to +300˚F temperature range, while the LM34C is rated for a −40˚ to +230˚F range (0˚F with improved accuracy). The LM34 series is available packaged in hermetic TO-46 transistor packages, while the LM34C, LM34CA and LM34D are also available in the plastic TO-92 transistor package. The LM34D is also available in an 8-lead surface mount small outline package. The LM34 is a complement to the LM35 (Centigrade) temperature sensor.

« previous  123456789