SEARCH

Found 2425 related files. Current in page 1

cara pasang water heater joven

1967 kb/s - Cara Pasang Water Heater Joven Full Download


2157 kb/s - [Verified] Cara Pasang Water Heater Joven


2864 kb/s - Cara Pasang Water Heater Joven Direct Download

Electric Insert Manual - Fireplaces
by bekapai 0 Comments favorite 1 Viewed Download 0 Times

INSTALLATION AND OWNER’S MANUAL Small Fireplace Insert (38” Wide) 98501001 Medium Fireplace Insert (40” Wide) 98501002 Large Fireplace Insert (42” Wide) 98501003 Read these instructions completely before beginning installation. Failure to follow them could cause a heater malfunction and result in serious injury and/or property damage. WARNING: All electric heaters have hot or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are stored. WARNING: This heater is tested and listed for use only with the optional accessories listed in these instructions. Use of optional accessories not specifically tested for this heater could void the heater warranty and/or result in a safety hazard. 1 Keep this manual for future reference. SAFETY INFORMATION Due to high temperatures, the insert should be located out of traffic and away from furniture and draperies. Do not place clothing or other flammable material on or near the insert. Never place any objects on the insert. The insert can become very hot when running. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. The insert will remain hot for a time after shutdown. Allow surfaces to cool before touching.

DF3015 - Electric Fireplaces
by bekapai 0 Comments favorite 1 Viewed Download 0 Times

Valued Customer, We are pleased that you have chosen to purchase an electric fireplace manufactured by Dimplex North America Ltd.Over the years, valuable memories will occur around the warmth and comfort of your hearth. Thank you for allowing our product to be the backdrop for those special moments. 7207500100REV05 QUICK REFERENCE GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE 1. Prior to the first use of the fireplace verify the following: • Are the circuit breakers for the socket the unit uses on? • Are the light bulbs in your fireplace loose? (to check, follow the instructions for replacing the light bulbs under the maintenance section of this manual) 2. The heater on your fireplace may emit a slight, harmless odor when first used. This odor is a normal condition caused by the initial heating of internal heater parts and will not occur again. 3. The information regarding the model of your fireplace can be found on the rating plate. See Page 2 for location. 4. If you have any technical questions regarding the operation or service of your fireplace have your Model and Serial Number ready, and contact Dimplex North America technical support at 1-888-DIMPLEX (1-888-346-7539) before returning the product to the point of purchase.

Electric Fireplaces - International Builders' Show

Electric Fireplaces BUI LT- I N | HD L I N E A R Just plug in one of our electric fireplaces for instant ambience in any room. All of our Built-in and HD Linear models are CSA tested for safety, fit any room style, and are easy to use. They are cool to the touch but will add warmth to any space. Columbia Corner Surround with Arched Rectangle built-in fireplace front shown in Cherry Stain Finish. A division of the Outdoor GreatRoom Company Electric LINEAR Cool to the touch and warm to the eye This hot fireplace feels cool to the touch, yet, puts out heat when you want it. It hangs like a piece of art – easy to install and sets up in minutes. Place it on any interior wall with an electric outlet. Just plug it in and have a beautiful fire instantly. Model GE-58 Select your ideal fire. Fireplace Features Choose from a large range of options – from fire intensity, to backlighting color, to heat range and more! • Ambient backlighting comes standard on all models. • High efficiency LED on fire and backlighting— Uses only 15 watts. • Operating costs as low as a penny per day with flame and backlighting, and 9-18 cents per hour with the heater on.

Electric Firep Electric Fireplace - Home Depot

INSTALLATION INSTRUCTIONS Location 1. The fireplace may be hanged on any wall surface that can support its weight and where it can be leveled. As it does not irradiate any heat from the back and no rear clearances are needed. 2. The heater, which is located at the base of the fireplace, must be a minimum of 16 inches away from any combustible material. 3. It is important that the wall on to which the fireplace is to be installed is of sound construction. It is recommended that the brackets are installed directly into beams for support. But not necessary depending on the size and weight of the unit. 4. Yosemite fireplaces are approved for indoor use only. 5. The fireplace must be kept away from any source of damp or moist conditions. Avoid any close contact with water. 6. This fireplace produces heat. Consequently it is important to ensure that a suitable wall covering is selected behind and around the appliance. Typical wood frame drywall construction is suitable. 2|P a g e Installation Figure 1 1. Select the position of the fireplace on the wall to which it is to be mounted. Draw a level horizontal line on the wall at the required height. This line will correspond to the top of the fireplace so it is important to allow for the extra height of the glass face. 2. Mark the center line of the fireplace on to the horizontal line. 3. Place the Installation Plate along the horizontal line and line up the center “V” cut out with the center line. See Figure 1. 4. DRYWALL INSTALLATION Install screws into studs at 4 outside corner screw holes. If studs are not present, install self drilling hollow wall anchors at the 4 outside corners and find wood studs with at least 4 more screws on the mounting plate (two high and two low). Holes are offset to allow finding wood studs at normal spacing. Attach more screws into larger models as needed.

Bi-Fuel CNG Sierra 2500HD Crew Cab - GM Fleet

Bi-Fuel CNG Sierra 2500HD Crew Cab Built for you. Propelled by innovation. When it comes to managing budgets and keeping an eye on the environment, business owners and fleet managers alike face many challenges. That’s where GM’s Bi-Fuel Sierra 2500HD Crew Cab comes in. It’s designed to help businesses reduce their fuel costs and environmental impact. ENGINEERED BY GM  The Bi-Fuel Sierra 2500HD Crew Cab uses a proven, 6.0L Vortec V-8 engine with factory-installed hardened intake and exhaust valves and valve seats. Unlike aftermarket solutions, the engine and all CNG fuel system components are engineered to meet GM’s rigorous standards for reliability, dependability and safety. GM’s validation tests include: full barrier testing (six separate tests), 10-year corrosion, mud trough, water fording, hot-weather evaluation (including trailering), cold-weather chamber testing, altitude testing and fuel gauge accuracy, among others. • The system automatically and seamlessly switches from CNG to gasoline when the CNG tank has been depleted. It also provides the flexibility to manually switch between the two fuels at any time.

Engine Driven Centrifugal Pump
by marechausse 0 Comments favorite 4 Viewed Download 0 Times

See Warranty on page 8 for important information about commercial use of this product. GPS400 Operating Instructions and Replacement Parts List Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Description The Wayne pumps are general use centrifugal water pumps. The pump is equipped with a Viton® seal assembly that is also compatible with many agricultural chemicals. Safety Guidelines This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols. Danger indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. Caution indicates a potentially minor or moderate injury. Notic indicates important information, that if not followed, may cause damage to equipment.

250 SERIES CENTRIFUGAL PUMPS
by marechausse 0 Comments favorite 1 Viewed Download 0 Times

Mud Hog™ Centrifugal Pump The SPD 2.5 in. Mud Hog™ Centrifugal Pump is designed and manufactured using the highest quality materials. Our Centrifugal pumps are available in sizes 3 x 2 x 13 in. through 8 x 6 x 14 in. to meet diverse flow rates in most applications. Through engineering design improvements and our dedication to continuous improvement to reduce repair cost and make repairs easier, SPD makes every attempt to provide the highest quality of products to our customers which meet our manufacturing tolerances and extend the life of the pump. SPD is committed to meeting and exceeding our customer’s expectations in an industry, which recognizes our products worldwide. The Mud Hog™ and all its features were designed with the customer in mind. Replacement parts are interchangeable with the Halco® 2500 Supreme centrifugal pumps, Mission® Magnum 1, and Mission® Magnum XL. SPD Centrifugal Pump, The MUD HOG™ Mud Hog™ Skid Packages  GENERAL INFORMATION SPD General Information GENERAL INFORMATION General Applications • Fresh water • Sea water • Drilling mud Standard Trim Includes • Frame - Cast Iron • Shaft* - 1045 Low Alloy Steel (AISI/SAE 1045) • Highest Quality Bearings - Steel • Shaft Sleeve* - 416 Stainless Steel • Casing* - Hard Iron/Cast Iron • Wear Pad* - Hard Iron • Labyrinth Seals/Isolators - Bronze • Mechanical Seal* - Heavy duty Tungsten Carbide with Viton® bellows • Impeller* - Hard Iron • Casing Nuts - Stainless Steel • All Pump Assemblies, Stuffing Box Covers and Casings hydrotested to 375 psig at no additional cost.

Phosphorus & Derivatives Market

[345 Pages Report] Phosphorus & Derivatives Market Report categorizes the Global Market of Phosphorus & Derivatives by Type (Ammonium and Industrial Phosphate, Phosphoric Acid) and by Application (Fertilizer, Water Treatment) to 2018"

Outer Banks
by obxstore 0 Comments favorite 13 Viewed Download 0 Times

The only thing greater than being on the Outer Banks is taking home a piece of the Outer Banks back home with you to enjoy throughout the year. Whether you love our family friendly beaches, the challenge of surfing or the incredible fishing opportunities, the waters surrounding the Outer Banks always leave us longing for another day of sun and salt water. History buffs love the Outer Banks for her lighthouses, the Wright Brothers and the Lost Colony.

PLUMBING REPAIRS
by plumbing360 0 Comments favorite 27 Viewed Download 0 Times

Plumbing 360 is your one-stop location for plumbing specialists in AZ. These reliable plumbers are at your service, whether you’re working on a large refurbishing project or have encountered a water heater emergency. Plumbing 360 is the best option.

« previous  123456789